Commissioning
B 3
ekrPro Com
60
web guide controller
EDV No.:
MD.191.01.05/1.6.x Chapter:
B 3
with analog sensors
Date:
23.11.2007
Page:
17/73
Slide 2
- Homing Direction – retraction direction and end switch
assignment
• at the first setting after switching on:
not
reversed
- Offset - positional offset to FVG position
• at the first setting after switching on:
Offset = 2000
Inverted = yes
- Range – Traversing range limits
• at the first setting after switching on:
min =
0.0
max = 5000.0
- Feed – Feed for stepping motor / gearing combination
This setting is treated as the feed per motor revolution for the
stepping motor / gearing combination.
The respective value is automatically entered when the FVG type
is selected:
for FVG 2MK60 = 20088
for FVG 2MK75 = 61666.
The manufacturer has entered this default setting and you are
only permitted to modify it (if necessary) after having obtained the
manufacturer’s agreement.
The relevant procedure then has to be agreed.
All warranty claims will be invalidated in any other case.
B 3.5.7.1.2 Configuration-independent default value
The following values are general settings, which can be selected
and entered as default values independently of the FVG selected.
- Retract Mode – free-running mode
• at the first setting after switching on:
SC & Man
- Norming Mode – Standardization Mode
Setting of the standardization mode is dependent on the type of
sensor being used.
Infrared sensors:
The mode is always set to "
bright/dark
“.
Ultrasonic sensors: The mode is always set to "
no norming
“.
- Width Adjust – FVG operating mode for center line guiding
• at the first setting after switching on:
Level Outer