Error reports
C 3
ekrPro Com
60
web guide controller
EDV-No.:
MD.191.01.05/1.6.x Chapter:
C
3
with analog sensors
Date:
23.11.2007
Page:
3/4
Fault
Possible cause
Solution
NORMING ERROR
-
An error has occurred during
sensor normalisation.
No guidance is possible.
-
Check sensor.
If necessary clean sensor.
-
Insert material and repeat
sensor normalisation.
EDGE DETECT. ERROR
-
During edge detection the
FVG slide has reached the
inner limit switch.
No guidance is possible.
-
Insert material and repeat edge
detection.
RETRACT TIMEOUT
-
Timeout during free-running
process of the sensor
positioning unit.
The slide of the sensor
positioning unit has not
reached the outer FVG limit
switch after elapsing of the
max. free-running time.
-
Check operation of the sensor
positioning unit (especially the
slide).
-
Check the limit switch of the
sensor adjustment unit.
WIDTH ADJ. ERROR
-
During guidance (automatic
operation), a slide of the
sensor positioning unit has
driven into an inner limit
switch.
The control unit changes to
manual operation.
The slide of the sensor
positioning unit moves
outwards (outer limit switch).
-
Check the position of the web of
material.
VOLTAGE BELOW 16V
-
The operating voltage has
fallen below 16 V.
Use according to regulations
is no longer guaranteed.
-
Ensure the stability of the supply
voltage.
Operating voltage range:
24 V ± 5%.