![Brother DCP 8085DN Скачать руководство пользователя страница 176](http://html.mh-extra.com/html/brother/dcp-8085dn/dcp-8085dn_service-manual_53152176.webp)
3-85
Confidential
13. OTHERS PROBLEMS
■
The machine is not turned on, or the LCD indication does not appear.
■
The fan does not work.
Step
Cause
Check
Result
Remedy
1
Harness
connection
failure of LCD
panel PCB
Is the harness of the
LCD panel PCB ASSY
connected correctly?
No
Reconnect the LCD panel
PCB ASSY harness.
2
LCD panel PCB
failure
Is the problem solved
after replacing the LCD
panel PCB ASSY?
Yes
Replace the LCD panel
PCB ASSY.
3
LCD panel failure Is the problem solved
after replacing the LCD
panel ASSY?
Yes
Replace the LCD panel
ASSY.
4
Low-voltage
power supply
failure
Is the problem solved
after replacing the LVPS
PCB unit?
Yes
Replace the LVPS PCB
unit.
5
Main PCB
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
(Verify the position of each fan referring to
Operational Check of Fans (Function
.
)
Step
Cause
Check
Result
Remedy
1
Harness
connection
failure of the
appropriate fan
Is the harness of the
appropriate fan
connected correctly?
No
Reconnect the harness of
the appropriate fan
correctly.
2
Charge HVPS
PCB failure
Is the problem solved
after replacing the
charge HVPS PCB
ASSY?
Yes
Replace the charge HVPS
PCB ASSY. Replace the
fuser unit fan (FU) and air
intake fan (AIR).
3
Low-voltage
power supply
failure
Is the problem solved
after replacing the LVPS
PCB unit?
Yes
Replace the LVPS PCB
unit. Replace the LVPS fan
(PS).
4
Main PCB
Is the problem solved
after replacing the main
PCB ASSY?
Yes
Replace the main PCB
ASSY.
Содержание DCP 8085DN
Страница 13: ...CHAPTER 1 SPECIFICATIONS ...
Страница 52: ...Confidential CHAPTER 2 THEORY OF OPERATION ...
Страница 69: ...2 16 Confidential 3 3 Paper Feeding Fig 2 18 LT path DX path MP path Paper tray path ...
Страница 89: ...CHAPTER 3 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 178: ...Confidential CHAPTER 4 PERIODICAL MAINTENANCE ...
Страница 204: ...4 25 Confidential 23 Secure the Fuser unit with the pan B M4x20 Taptite screw Fig 4 37 Taptite pan B M4x20 Fuser unit ...
Страница 248: ...CHAPTER 5 DISASSEMBLY REASSEMBLY ...
Страница 265: ...5 12 Confidential Fig 5 7 EM2 4 places Separation pad ASSY ...
Страница 291: ...5 38 Confidential 38 Driver PCB Battery CIS model Main PCB Battery harness Drive PCB Battery Driver harness ...
Страница 400: ...5 147 Confidential 9 11 3 Printed Rubber Key 1 Remove the Printed rubber key Fig 5 170 Printed rubber key Panel cover ...
Страница 452: ...5 199 Confidential 9 33 Thermistor ASSY 1 Remove the Thermistor ASSY from the Frame L Fig 5 242 Frame L Thermistor ASSY ...
Страница 501: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 507: ...6 5 Confidential 8 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Страница 516: ...CHAPTER 7 SERVICE MODE ...
Страница 525: ...7 7 Confidential For color scanning Fig 7 2 ...
Страница 527: ...7 9 Confidential For white and black scanning Fig 7 3 ...
Страница 528: ...7 10 Confidential For color scanning Fig 7 4 ...
Страница 567: ...Confidential CHAPTER 8 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Страница 569: ...8 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram Fig 8 1 ...
Страница 570: ...8 2 Confidential LVPS PCB Circuit Diagram 230V Fig 8 2 ...
Страница 571: ...8 3 Confidential LVPS PCB Circuit Diagram 115V Fig 8 3 ...