Endian Control (Byte and Word Swapping)
BCM5718 Programmer’s Guide
Broadcom
®
January 29, 2016 • 5718-PG108-R
Page 202
Word Swap Non-Frame Data = 1 and Byte Swap Non-Frame Data = 1
This requires the software to use the following big-endian data structure on the host:
Table 73: Send Buffer Descriptor (Big-Endian 32-bit format) with Word and Byte Swapping
Byte #
0
1
2
3
Bit #
31
15
MSB
Host Address
0x00
0x04
MSB
Length
Flags
0x08
Reserved
VLAN
0x0C