SerDes PHY Register Definitions
BCM5718 Programmer’s Guide
Broadcom
®
January 29, 2016 • 5718-PG108-R
Page 551
MII Status
Register Description:
MII Status Register.
Register Offset:
0x1 at Block 0
Table 127: MII Status
Bits
Name
RW
Description
Default
15
100BASE_T4
RO
0 = Incapable.
1 = 100Base-T4 capable.
0
14
100BASEX_FDX
RO
0 = Incapable.
1 = 100BASE-X full-duplex capable.
0
13
100BASEX_HDX
RO
0 = Incapable.
1 = 100BASE-X half-duplex capable.
0
12
10BASET_FDX
RO
0 = Incapable.
1 = 10BASE-T full-duplex capable.
0
11
10BASET_HDX
RO
0 = Incapable.
1 = 10BASE-T half-duplex capable.
0
10
10BASET2_FDX
RO
0 = Incapable.
1 = 10BASE-T2 full-duplex capable.
0
9
10BASET2_HDX
RO
0 = Incapable.
1 = 10BASE-T2 half-duplex capable.
0
8
EXT_STATUS
RO
0 = No extended status.
1 = Extended status in register 0x0F.
1
7
RESERVED
RO
Reserved write 0, ignore read.
0
6
MF_PREAMBLE_SUP
PRESSION
RO
0 = PHY does not accept management frames with
preamble suppressed.
1 = PHY accepts management frames with preamble
suppressed.
1
5
AN_COMPLETE
RO
Auto-negotiation complete.
0 = Incomplete.
1 = AN complete.
0
4
RF
RO
Remote fault.
0 = No fault detected.
1 = Remote fault detected.
0
3
AN_ABILITY
RO
Auto-negotiation ability.
0 = Incapable of AN.
1 = AN capable.
1
2
LINK_STATUS
RO
Link status.
0 = Link fail.
1 = Good link.
0
1
JABBER_DETECT
RO
Jabber detect
0 = Not detected
1 = Jabber detected
0