FT800 Series Programmer Guide
Version 2.1
Document Reference No.: BRT_000030 Clearance No.: BRT#037
46
Copyright © Bridgetek Limited
Register Definition 23
REG_TAG_X Definition
31
9 8
0
Address: 0x102470
Reset Value: 0x0
Note: NONE
REG_TAG_X Definition
Bit 0 - 8 : These bits are set by host as X coordinate of touching point, which
will enable host to query the tag value. This register shall be used together
with REG_TAG_Y and REG_TAG. Normally, in the case the host has already
captured the touching point's coordinator, this register can be updated to
query the tag value of the respective touching point.
Reserved
R/W