Maintenance of the ATEX cleaner is mandatory after a maximum of 150
operating hours. Depending on the operating conditions, the operator must
specify shorter maintenance intervals.
The performed maintenance must be logged.
Only original
Breconcherry
maintenance and wear kits intended for ATEX
may
be used.
If the maintenance instructions are not followed, the cleaner loses its ATEX
conformity and must not be used in explosive areas.
5.10
Flow and operational parameter monitoring for orbital cleaners
In order to ensure that the orbital cleaner is operated with fluid, the operator must
use a suitable monitoring system.
ATEX approved flow monitoring systems recommended by
Breconcherry
:
•
Flow switch type SF311A; Manufacturer ifm electronic GmbH
•
Evaluation unit type SR2301; Manufacturer ifm electronic GmbH
•
Evaluation unit type SN2301; Manufacturer ifm electronic GmbH
The instructions and manufacturer's instructions for maintenance and calibration
of the flow monitoring system must be taken into account. The ignition protection
system should have ignition protection level b1, (see EN ISO 80079-37:2016).
The monitoring of the temperature, the pressure and the flow volume must be
guaranteed, (see chapter “Operating Conditions” Section 2.3, Page 9).
Maintenance
Flow and operational parameter monitoring for orbital cleaners
430BAL011767EN_3
28.05.2018