4.2
Selection of the cleaning parameters according to TRGS 727:2016
For the information,
Breconcherry
assumes no responsibility. If there
is a risk of
explosion due to the use of cleaners, all current ATEX relevant
standards and
regulations must always be applied.
4.2.1
Cleaning with water jets with pressures of up to 12 bar
When cleaning with water jets up to 12 bar and with up to 20 nozzles, no
dangerous charges are to be expected as long as the liquid flow rate does not
exceed 7 l/s and the tank volume does not exceed 10 m
3
.
4.2.2
Clean with solvents of low and medium conductivity from pressures up to 12 bar
(1) When cleaning liquids of low and medium conductivity, e.g. organic solvents,
are used, the proportion of a second phase, e.g. water or solid, may not exceed
1%.
(2) Cleaning agents may only be run in a closed circuit if the impurities are kept
below 1%.
Hint!
The accumulation of liquid in the container during cleaning should be
avoided.
Hint!
Low-conductivity liquids, such as hydrocarbons, are less charged
during spraying than water because they contain only a small
concentration of dissociated ions.
Cleaning
Selection of the cleaning parameters according to TRGS 727:2016
430BAL011767EN_3
16
28.05.2018