6.1.2
Additional restrictions on usable substances
Depending on the type of detergent, there may be additional restrictions on the
substances to be used. Please observe the manufacturer’s or conformity
declarations.
6.2
Instructions for the operation of the cleaner
On the operating side, a temperature limiter (temperature sensor) must be
available for switching off of the system. The settings must be adjusted so that
the maximum permissible temperatures are never reached.
See EN ISO 80079-36:2016 and other regulations that must be applied for
cleaning with explosive mediums.
6.3
Explosion groups
The classification of gases is based on their specific ignitability, which is
determined by standardized figures.
Explosion groups
Typical gas
IIA
Propane
IIB
Ethylene
IIC
Hydrogen
The danger increases for the explosion groups from IIA to IIC.
6.4
Substance classification
The substance classification depends on the temperature classes and explosion
groups. Once all substance data has been recorded, a cleaner can be selected
according to the specified temperature class and explosion group.
Additional information on cleaner selection
Instructions for the operation of the cleaner
430BAL011767EN_3
28.05.2018