I s - C r e a m
30
5 ALARMS
If an anomaly occurs during operation, the machine will display the alarm icon and relevant code.
figure 6
P04
:
V2
Electric motor rotation speed during ice cream conservation (total
reduction ratio i=48:1)
rpm
000…6000
0
P05
:
V3
Electric motor rotation speed during ice cream dispensing (total re-
duction ratio i=48:1)
rpm
500…6000
6000
P06
:
BL_T
Lock touch display after 180 seconds of inactivity
-
ON/OFF
OFF
P07
:
CS
Unlock display code
Xxxx
4-Digit number
0000
P08
: C_F
Temperature scale: allows you to select the temperature rep-
resentation system used
°C/°F
C…F
C
P09
: PSW_U
User password: if equal to 0000 (default value), it allows the oper-
ator to change the parameters from PA01 to PA09. If it is different
than 0000, it allows you to block access to the operating parame-
ters from PA01 to PA09.
-
4-Digit number
0000
P10
: PSW_M
Maintenance password: required in order to change the parameters
and allows you to block access to the parameters
-
4-Digit number
1234
P11
: PL
Lights present: if set on YES, the icon for turning the lights on and
off is displayed
-
SI/NO
SI
P12
: DMAXG
Maximum ice cream density
W
0...400
300
P13
: IDG
Ice cream density hysteresis
-
0…4,0
2
P14
: ITRP
Product reserve temperature hysteresis
°C/°F
0…2
1
P15
: TOFFC
Compressor OFF safety time
S
0…600
60
P16
: TOFFV1
Ice cream cylinder solenoid valve OFF safety time
S
0…600
30
P17
: TOFFV2
Product reserve solenoid valve OFF safety time
S
0…600
30
P18
: TAV
Time for which the density must remain above the DG value
S
0…60
5
P19
: TC
Condenser temperature
°C/°F
30...60
45
P20
: TCD
Density restoration interval: interval at the end of which the ice
cream density is checked and restored
S
0…3600
600
P21
: DM
Minimum density restoration cycle duration
S
0…3600
10
P22
: AMAX
Motor protection: maximum motor absorption that can be reached,
after which the gear motor is stopped to prevent damage
W
0…500
400
P23
: TR
Motor stop time: time for which the gear motor is stopped
S
0…600
90
P24
: RP
Motor protection delay: time for which the absorption must remain
above AMAX in order to trigger the motor protection
S
0…60
3
P25
: TMAX
Product conservation alarm temperature: maximum temperature
permissible for the product reserve, above which the product high
temperature alarm is displayed
°C/°F
0…10
8
P26
: PID_P
Motor control proportional constant
-
To be confirmed
20,0
P27
: PID_I
Motor control integral constant
-
To be confirmed
0,4
P28
: PID_D
Motor control derivative constant
-
To be confirmed
0