Installation
18
Reflective Sensor
The reflective sensor is used to detect notched material as well as to detect
black marks on the back of label stock. There is a clear label covering the
reflective sensor. (When operating in Brady mode, the LCD display will show
sensor placement information
.)
Brady Mode
1. The LCD will indicate Brady mode
and show sensor
placement information
.
2. Open the cover
(Figure 1, 9)
lower the control panel
(Figure 1, 17)
, and
press the green print module release button
.
3. Adjust the sensor knob
with a pointed tool to the position
displayed on the LCD
(Figure 14, 2)
.
. Lift the control panel
and press firmly until the panel clicks into position.
5. Close the cover
.
Standard Mode
1. Open the cover
(Figure 1, 9)
lower the control panel
(Figure 1, 17)
, and
press the green print module release button
.
2. Adjust the sensor knob
with a pointed tool until the sensor
inside the sensor window
is aligned with the edge of the
labels. If the label material is notched, the sensor must be aligned with the
notch.
3. Lower the print module
(Figure 1, 14)
. Lift the control panel
and press firmly until the panel clicks into position.
4. Close the cover
.