Adjusting the Vernatherm Thermostatic Mixing Valve
NOTE: This valve is NOT factory preset. Upon installation, the temperature of this valve must be
checked and adjusted to ensure delivery of a safe water temperature. Water in excess of 110°F
(43°C) may cause scalding.
1. Check the temperature when approximately 1.0 GPM water flow is reached and adjust if
necessary (the range of the valve is 95°F–115°F (35°C–43°C). To adjust the temperature, follow
the procedure below:
• Loosen temperature locking nut with wrench.
• Using a blade screwdriver, turn the adjustment stem
counterclockwise
to
increase
the
temperature or
clockwise
to
decrease
the temperature (Figure 13).
• Once desired temperature has been reached, tighten lock nut to prevent change in temperature.
2. Shut the hot water inlet off by closing the hot water stop-strainer-check valve. While the hot
water supply is turned off, check to make sure the cold water flow is reduced. If the cold water
is reduced properly, reopen the hot water supply.
3. Shut the cold water inlet off by closing the cold water stop-strainer-check valve. While the cold
water supply is off, check to make sure that the hot water flow has shut down.
TEMPERATURE
ADJUSTMENT
STEM
TEMPERATURE
LOCKING
NUT
Figure 13