Classic Circular 36"/54" Washfountain with Foot Control
WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
16
4/6/2007
Installation Instructions continued . . .
Figure 12
Figure 11
Step 7: Installing the Operating Rod
1. Insert the operating rod in the operating rod lever and then into the foot lever (see Figure 11).
NOTE: For normal operation, use the operating rod as shipped. The spring loaded cartridge should
be adjusted so there is no play in the operating lever. Care must be taken to insure that a snug fit is
achieved without activating the foot valve or water will leak from the sprayhead (see Figure 11).
2. When movement of the operating rod is insufficient to open the foot valve, disassemble the rod
and remove the spacer and override spring. Reassemble the operating rod as shown in Figure 12.
Reinstall and adjust so that the foot valve is completely open when the foot lever is fully
depressed. This prevents damage to the foot valve due to the absence of the override spring.
3. Turn supplies on and activate the sprayhead. Check piping installation for leaks.
4. Clean the sprayhead if necessary. See page 22 for sprayhead troubleshooting. Adjust the volume
control valve, if necessary, to control the flow of water.