Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions
WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
7
4/6/2007
Centerline of
Washfountain
Centerline of
Wa
shfountain
Centerline of
Washfountain
See rough-ins
on Pages 5-6
for dimensions
not shown
Types B, H
Types A, O
With Tie Pipe
Bracket Option
Types A, O
2" NPT Coupling if Tie
Pipe is not required
(Supplied by Installer)
Vent
or
Tie Pipe
(Supplied by Installer)
Vent
or
Tie Pipe
(Supplied by Installer)
Vented Trap
(111-024)
Optional
Tie Pipe Bracket
(S70-082)
4"
(102)
4"
(102)
B – See
Table 1
B – See
Table 1
B – See
Table 1
4"
(102)
Installation Instructions
Step 1:
Rough-In of Drain & Supplies
1. Rough in supply and drain piping as required for your installation (see pages 5-6 for rough-ins of
the optional installations).
2. Assemble the drain to the dimension shown in Figure 1 and Table 1 for bowl size of the
Washfountain you are installing.
NOTE:
All piping shown in dotted lines to be supplied by the installer. Compliance and conformity to
local codes and ordinances is the responsibility of the installer.
Figure 1
Material
Size
Dim
Standard Height
Juvenile Height
Terrazzo
54"
B
18-5/8" (473mm)
14-5/8" (371mm)
Stainless Steel
54"
B
17" (432mm)
N/A
Terrazzo
36"
B
18-5/8" (473mm)
14-5/8" (371mm)
Stainless Steel
36"
B
17-3/8" (441mm)
N/A
Table 1 — “B” Trap Dimensions