Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions
WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
15
4/6/2007
Installation Instructions continued . . .
Step 6: Installing the Valve Assembly
NOTE: Flush supply lines before making connections.
1. Connect the stop-strainer-check valves, mixing valve, volume control valve, and foot valve as
shown in Figure 10.
2. For overhead supply lines, install 1/2"nominal copper supply tubing by passing the lines through
the holes in the dispenser cover and then down through the support tube.
3. Install the valving assembly using suitable fittings to the supplies as shown in Figure 10 at the
approximate height indicated in Table 2.
4. Slide the tailpiece nut over the tailpiece and connect the tailpiece to the supply pipe (or to the
nipple/coupling for B or H drain).
Operating Lever
Coupling
(169-174)
Nut
(110-005)
Tailpiece
(129-009)
Nipple
STD: 2" Long (113-852)
JUV: Close (113-006AL)
Tailpiece Washer
(124-001AF)
Used on "B"
and "H" models only
To Supply Pipe
Foot Valve
(S07-066)
OPTIONAL Vernatherm™
Thermostatic
Mixing Valve
(S01-525)
(Units are supplied with
Manual Mixing Valve as
standard equipment)
Stop-Strainer-Check
Valve
(S60-003)
Washer
(124-001AF)
Nut
(110-005)
Tailpiece
(129-007)
Manual Mixing
Valve
(S01-038)
Valve Assembly
Distance (dimension)
finished floor - see
Table 2
Figure 10
Model Number
Type A
Type B
Type H
Type O
Standard Height
9" (229mm)
6-3/16" (157mm)
6-3/16" (157mm)
9" (229mm)
Juvenile Height
5-1/4" (133mm)
3-7/16" (87mm)
3-7/16" (87mm)
5-1/4" (133mm)
Table 2 — Distance to Finished Floor