Lenox® Lockers (includes Cubby & “Z” Lockers)
Installation
9
Bradley Corporation • LK-INSTR-001 Rev. K; EN 07-1303
10/24/07
Installation Instructions continued . . .
Step 7a: Optional Locker Slope Top Installation
NOTE: Standard 3-tier lockers are shown in Figures 7a–7e. Slope and
flat tops for Cubby and “Z” lockers are similar.
NOTE: The slope tops are shipped in standard lengths and can be
easily modified during installation. This modification is often
necessary to overcome a variety of installation situations. Use a panel
saw to cut the slope top sections to the proper length if necessary.
NOTE: Use the corner slope top in the corner as shown in Figure 7c
on page 10.
NOTE: Corner slope tops should only be trimmed when they extend past the edge of the locker.
NOTE: Wall strips will be 54" maximum length. Color of wall strips may vary.
1. Drill the appropriate number of 3/16" dia. clearance holes through the top of the installed
lockers,
making sure that the holes are located 1-1/4" from the front edge of the locker. This
dimension is critical to ensure proper installation (see Figure 7a)
.
• Locker screw hole requirements: slope
tops less than 18" long, two holes;
18"–35" long, three holes; 36"–45"
long, four holes; 72" long, six holes.
2. Position the wall strip (or strips) on top
of the lockers flush against the wall as
shown in Figure 7b. Measure, scribe and
drill 1/4" mounting holes into the wall
strip as follows:
• CONCRETE/BLOCK WALLS: Start
1" from each end and space holes
equally (do not exceed 16" on
centers). The holes must be located at
least 1-1/4" from the bottom edge of
the wall strip. Use a 3/16" masonry
drill bit and 1/4 x 1-3/4" Lg. Tapcon
screws to anchor the wall strip to the
wall.
• STUD WALLS: Drill the mounting
holes at every stud location covered
by the wall strip. The holes must be
located at least 1-1/4" from the bottom
edge of the wall strip. Anchor the wall
strip to the wall with #14 x 1-3/4" Lg.
pan head screws.
Locker slope top installation instructions
continue on page 10.
Figure 7a
Figure 7b
WALL STRIP
1-1/4"