Installation Instructions
Step 1: Optional Locker Base Installation
IMPORTANT: Make sure the base is square AND level before anchoring to the floor (the
base may be square but not level so be sure to check both). This will ensure proper locker
operation.
NOTE: The base sections are shipped in standard lengths and come with slotted end caps. The length
of the base sections can be easily modified during installation by cutting one end to the desired
length. DO NOT cut the end caps
.
1. Measure and scribe placement lines for the locker base sections.
2. Position the base sections per submittal layout. The ends of the base sections fit into the slots in
the end caps (see Figure 1). Square and plumb the sections and end caps using shims as required.
If shims are used, place them under the mounting brackets perpendicular to the bracket.
3. For longer locker runs, the base sections may need to be connected together. Use the mending
plate and #10 x 1/2" screws provided to connect pieces (see inset, Figure 1).
4. Using the applicable mounting hardware supplied, anchor the base sections to the floor. Use a
3/16" masonry drill bit for 1/4 x 1-3/4" Tapcon screws (see inset, Figure 1).
Lenox® Lockers (includes Cubby & “Z” Lockers)
Installation
4
10/24/07
Bradley Corporation • LK-INSTR-001 Rev. K; EN 07-1303
Figure 1
ANGLE
BRACKET
(HW0018)
WALL/FLOOR INTERSECTION
END CAP
LOCKER BASE (FOR
WALL-MOUNTED
LOCKERS)
LOCKER BASE (FOR
ISLAND LOCKERS)
#10-1/2" LG.
SCREW
(FAST-T349)
1/4 x 1-3/4" LG.
TAPCON SCREW
(FAST-LF015)
ISLAND BASE
END CAP
MENDING PLATE
(HW0048)