Service menu
Sense II – 6 720 818 367 (2015/10)
Type of building
If damping is activated, the adjustment of the outside
temperature fluctuations can be set with the building type. By
adjusting the outside temperature, thermal inertia
(responsiveness of heat-up times depending on outside
temperature) of the building is taken into account. Thus, by
setting the building type, the control can be adapted to suit the
characteristics of the building.
The building type affects the heat-up times.
Fig. 22
Example for adjusted outside temperature:
[1]
current outside temperature
[2]
adjusted outside temperature
This example shows how the adjusted outside temperature
follows the current outside temperature, but does not reach its
extreme values.
The current values of the adjusted and the measured outside
temperature
7.1.2 Boiler data menu
Heat source-specific settings, e.g. the maximum heat output or
the pump logic, can be made in this menu. Further information
is available in the technical documentation of the relevant heat
source or control module. These settings are only available if
the system is designed and configured accordingly (e.g. in
systems without cascade module).
Hamburg
– 12
Rome
– 1
Helsinki
– 24
Sevastopol
– 12
Istanbul
– 4
Stockholm
– 19
Copenhagen
– 13
Valencia
– 1
Lisbon
0
Vienna
– 15
London
– 1
Zurich
– 16
Madrid
– 4
Adjustment Type
Effect
Light
for example,
prefabricate
d building,
wood-frame
construction
•
low adjustment of the
outside temperature
•
Where heat-up times are
quick the flow temperature
from the heat source
(boiler) is maintained for a
short period of time.
Medium
for example,
uninsulated
cavity wall
construction
(default
setting)
•
medium adjustment of the
outside temperature
•
Where heat-up times are
quick the flow temperature
from the heat source
(boiler) is maintained over
a normal period of time.
Heavy
for example,
fully
insulated
brick house
•
high adjustment of the
outside temperature
•
Where heat-up times are
quick the flow temperature
from the heat source
(boiler) is maintained for a
long period period of time.
Table 18 Building types
Minimum outside temperature in °C
Table 17 Minimum outside temperatures for Europe
In the default setting any changes in the
outside temperature have an effect after a
maximum delay of three hours on the
calculation of the weather-compensated
control.
▶ To monitor the adjusted and the measured
outside temperature: open the
Diagnosis
>
Monitored values
>
Boiler /
burner
menu (only current values).
▶ To view the course of the outside
temperature of the last 2 days: open the
Info
>
Outdoor temp.
>
Outdoor temp.
curve
menu
6720 645 480-30.1O
2
1
0°C
20°C
0 h
12 h
24 h