41
Service menu
Sense II – 6 720 818 367 (2015/10)
Fig. 27
Screed drying process with default settings
t
Time in days
T
VL
Flow temperature
Endphase duration
No end phase
Time lag between the beginning of the end phase (last temperature step) and
the end of the screed drying program (
Permanently
1
... 30 days
End phase temperature
20 ...
25
... 55 °C
Flow temperature during end phase (
Max. interruption time
2 ...
12
... 24 h
Maximum duration of a screed drying interruption (e.g. through stop of the
screed or power failure) until a fault display is output.
Screed dry. system
Yes
Screed drying is active for all heating circuits of the system
Notice
: Single heating circuits cannot be selected. DHW heating is not
possible. The menus and menu items with settings for DHW are disabled.
No
Screed drying is not active for all heating circuits
Notice
: Single heating circuits can be selected. DHW heating is possible. The
menus and menu items with settings for DHW are enabled.
Screed dry. H. circ. 1 ...
Screed dry. H. circ. 4
Yes
Screed drying in the selected heating circuit is active/not active
No
Start
Yes
Start screed drying now
No
Screed drying not yet started or terminated
Cancel
Yes
Temporarily stop screed drying. If the maximum interruption duration has
been exceeded, a fault display is output.
No
Continue
Yes
Continue screed drying after stop.
No
Menu item
Adjustment range
description
Table 23 Setting in the Screed drying menu (Fig. 27 shows the default setting of the screed drying program)
6720 645 480-31.2O
20°C
30°C
40°C
50°C
60°C
1
0
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22
t
T
VL
2
3
1
6
5
4
7