34
Service menu
Sense II – 6 720 818 367 (2015/10)
Max. flow
temperature
30 ...
75
... 85 °C
The maximum flow temperature can only be adjusted in room-temperature
dependent control mode (via weather-compensated part of the heating curve).
The adjustment range depends on the selected heating system.
Set heating
curve
Fine adjustment of the heating curve that is preset via the heating system (
the heating system and heating curve for weather-compensated control, page 36)
Setback type
Reduced mode
Further information on the setback type for the selected heating circuit
(
Outside temperature
threshold
Room temperature
threshold
Reduced mode
below
– 20 ...
5
... 10 °C
Temperature for the setback type Outside temperature threshold
(
Heat constantly
below
Off
The heating system operates independently of the adjusted outside temperature
in the active operating mode (
Heat constantly below a certain outside
– 30 ... 10 °C
If the adjusted outside temperature falls below the value set here, the heating
system automatically changes from the setback mode into the heating mode
(
Heat constantly below a certain outside temperature, page 39).
Frost protect
Notice
: To ensure frost protection for a constant heating circuit or the entire
heating system, select outside temperature-dependent frost protection mode.
This setting is independent of the set control type.
Outdoor temp.
Frost protection is deactivated/activated on the basis of the temperature
selected here (
Frost protection limit temperature (outside temperature
Room temperature
Room and outdoor temp.
Off
Frost protection off
Frost prot. limit
temp.
– 20 ...
5
... 10 °C
Frost protection limit temperature (outside temperature threshold), page 39
Mixer
Yes
Selected heating circuit with mixer
No
Selected heating circuit without mixer
Mixer runtime
10 ...
120
... 600 s
Mixer running time from fully closed to fully open for the relevant heating circuit
Mixer increase
0 ...
5
... 20 K
Enter heat production increase for mixer
DHW priority
Yes
DHW heating is activated, the central heating requirement of the heating system is
interrupted
No
DHW heating is activated, the central heating requirement of the heating system is
being met simultaneously (if the installed hydraulic arrangement allows)
Shown in
standard
display
Yes
The selected heating circuit is visible in the standard display. The change between
automatic mode and manual operation in the corresponding heating circuit is
possible from the Sense II as well (with or without remote control).
No
The selected heating circuit is not visible in the standard display. The change
between automatic mode and manual operation is not possible. If there is no
remote control installed for the selected heating circuit, settings can be made as
usual through the main menu, e.g. temperature levels of the operating modes and
time programs.
Menu item
Adjustment range
description
Table 20 Check settings in the heating circuit 1 – 4