23
Commissioning
Sense II – 6 720 818 367 (2015/10)
Setback type
Which setback type should be used ? (for further
information
Reduced mode
|
Outside
temperature threshold
|
Room
temperature threshold
Reduced mode
below
When
Setback type
=
Outside temperature
threshold
: Below what temperature should the
reduced mode be activated?
– 10 – 20 °C
Frost protect
Is frost protection set? What temperature should the
frost protection be activated by?
Outdoor temp.
|
Room
temperature
|
Room and outdoor
temp.
|
Off
Mixer
Does Heating Circuit 1 have a mixer installed?
Yes
|
No
Mixer runtime
How long does it take until the mixer in heating
circuit 1 rotates from one stop to the other? (fully
closed to fully open)
10
–
600 s
DHW priority
Should the heating system be deactivated during DHW
heating?
Yes
|
No
Heating circuit 2
, ...,
Heating
circuit 4
See
Heating circuit 1
DHW system I
DHW system I
install.
Is a DHW system installed? Where is DHW system I
electrically connected?
No
|
At the boiler
|
At the module
Config. DHW
at boiler
How is the DHW system I hydraulically connected?
No DHW
|
3-way valve
|
Primary
pump
DHW
What DHW temperature should be set?
For example
15 – 60 °C
DHW reduced
What reduced DHW temperature should be set?
For example
15 – 60 °C
DHW circ.
pump installed
Is an additional DHW circulation pump installed in the
DHW system?
No
|
Yes
DHW
circulation
pump
If a DHW circulation pump is installed: Is this pump
controlled by the heat source?
On
|
Off
DHW system II
See
DHW system I
Solar
Solar thermal
sys installed
Is a solar system installed?
If a solar system is installed (
Yes
), there are additional
menu items in the menu
Solar
(
technical
documentation of the solar system).
No
|
Yes
Start solar thermal system
Fill and vent the solar thermal system. Check the
parameters for the solar thermal system and, if
necessary, adjust them to suit the installed solar
thermal system. Check the following before starting
the solar thermal system:
•
Solar thermal system filled and vented?
•
Parameters of the solar thermal system checked or
adjusted to the installed solar thermal system?
Commissioning the solar thermal system?
Yes
|
No
Confirm configuration
Do the settings match with the installed system?
Confirm
|
Back
Menu item
Question
Answer/setting
Table 14 Commissioning with the configuration wizard