![Bosch Solution 64 Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/bosch/solution-64/solution-64_installers-manual_39390095.webp)
Solution 64 | Installer Guide | System Programming
Bosch Security Systems | 11/05 |
11-11
Timer Group
Setting this option will assign the start and stop times to a Timer
Group to restrict user access to doors and areas. The INDEX defines
the Timer Group to link to. See MENU 1-4-4 — Timer Group for
information on assigning users to timer groups.
System > Schedules >
Index
MENU 7-5-4
0
This menu allows you to program which Area, Output or Timer
Group the Schedule will operate. The index type is determined
by the schedule function which was selected in MENU 7-5-3.
Enter [MENU] + [7] + [5] + [4] and use the up and down arrows
to highlight the Schedule in the list then press [OK].
Alternatively, you can enter the Schedule number directly and
press [OK].
Sk001 Schedule 1 Name
Sk002 Schedule 2 Name
Sk003 Schedule 3 Name
Press
OK or MENU
Using the numeric keys, enter the number of the Area, Output
or Timer Group that the schedule is to follow then press [OK] to
save and exit or press [MENU] to exit without saving.
Index Sk001
000
Press 0-9 OK to SAVE
System Holidays
The Solution 64 has proSolution for up to 8 individual holiday
time periods which can be used to allow or deny access to
users or to operate outputs via schedules. Holidays are defined
by setting a start and stop date so it is possible to create 1
system holiday that spans multiple days. For example the
holiday could start on the 1st Jan and end on the 5th Jan.
System > Holidays >
Name
-
MENU 7-6-0
H
o
l
i
d
a
y
1
N
a
m
e
This menu allows you to program a 16 character text name for
each holiday.
Enter [MENU] + [7] + [6] + [0] and use the up and down arrows
to highlight the Holiday in the list then press [OK].
Alternatively, you can enter the Holiday number directly and
press [OK].
H001 Holiday 1 Name
H002 Holiday 2 Name
H003 Holiday 3 Name
Press
OK or MENU
1)
3)
1)
User the arrow and number keys to move and change text.
When the Holiday Name is complete, press [OK]. At any time
you can press the [OFF] key to clear the text from the current
cursor position to the end of the line.
Name H001
Holiday 1 Name
Press
0-8 OK to SAVE
i
Note
See Alpha Text Programming in Section 4 - Programming
Overview for further detail on entering alpha text.
System > Holidays >
Start Stop Dates
-
MENU 7-6-1
Start 12am
Stop 12am
01
Jan
01
Jan
DD
MM
DD
MM
This menu allows you to program the start and stop date for
each holiday period. Holidays can be as short as one day or as
long as 364 days.
Enter [MENU] + [7] + [6] + [1] and use the up and down arrows
to highlight the Holiday in the list then press [OK].
Alternatively, you can enter the Holiday number directly and
press [OK].
Use the up and down arrow keys to select the holiday that you
want to change, then press [OK]. Alternatively, you can enter
the holiday number, then press [OK]. The keypad will display
the holiday start date:
Holiday Dates H001
Start 12am Stop 12am
01 Jan 01 Jan
Press
OK to SAVE
To program, use the left and right arrows to scroll the cursor
left and right between the holiday day and month options and
use the up and down arrow keys to scroll the day and month.
Press [OK] to save and exit or press [MENU] to exit without
saving.
i
Note
If the start day and month equals the stop day and month then
no holiday exists. There must be a difference between start and
stop dates.
2)
1)
2)
3)
4)