![Bosch Solution 64 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/bosch/solution-64/solution-64_installers-manual_39390089.webp)
Solution 64 | Installer Guide | System Programming
Bosch Security Systems | 11/05 |
11-5
When finished press [OK] to save and exit or press [MENU] to
exit without saving.
Australian Daylight Savings Times
At the time of writing this document QLD, the NT and WA do
NOT participate in daylight savings.
In NSW, VIC, ACT, SA daylight savings begins at 2:00 am on the
last Sunday in October and ends at 3:00 am on the last Sunday
in March.
Daylight Saving Begins
Daylight Saving Ends
Turn Clock Ahead 1 hr
Turn Clock Back 1 hr
Sun 26 Oct 2003
Sun 28 Mar 2004
Sun 31 Oct 2004
Sun 27 Mar 2005
Sun 30 Oct 2005
Sun 26 Mar 2006
Sun 29 Oct 2006
Sun 25 Mar 2007
In Tasmania, daylight savings begins at 2:00am on the first
Sunday in October and ends at 3:00am on the last Sunday in
March
Daylight Saving Begins
Daylight Saving Ends
Turn Clock Ahead 1 hr
Turn Clock Back 1 hr
Sun 5 Oct 2003
Sun 28 Mar 2004
Sun 3 Oct 2004
Sun 27 Mar 2005
Sun 2 Oct 2005
Sun 26 Mar 2006
Sun 1 Oct 2006
Sun 25 Mar 2007
System Timers
System > Timers >
Exit Time
MENU 7-2-0
0
6
0
SECONDS
This menu sets the exit time delay period for all areas on the
system. The exit timer starts when an area is armed in the On
and Part On modes. The keypad will sound an exit warning
tone while the exit timer is running. Exit delay time can be
programmed between 0 and 255 seconds.
(*** System Wide Parameter ***)
Press [MENU] + [7] + [2] + [0]. The keypad will display the
current Exit Time.
Exit Time
060 Seconds
Press 0-9 OK to SAVE
Using the numeric keys, enter the required Exit Time in
seconds. Valid times are 0 - 255 seconds 0 = No Exit Time.
Press [OK] to save and exit or press [MENU] to exit without
saving.
3)
1)
2)
3)
System > Timers >
Entry Time 1
MENU 7-2-1
0
2
0
(*** System Wide Parameter ***)
SECONDS
This menu sets the entry time delay for zones programmed as
entry delay 1 zones. Entry Time 1 is common for all areas on
the system.
When a zone programmed as Delay 1 is triggered, the entry
time will start and the keypad will sound an entry warning
tone. Entry Time 1 can be programmed between 0 and 255
seconds.
Press [MENU] + [7] + [2] + [1]. The keypad will display the
current Entry Time 1 delay.
Entry Time 1
020 Seconds
Press 0-9 OK to SAVE
Using the numeric keys, enter the required delay for Entry Time
1 in seconds. Valid times are 0 - 255 seconds 0 = No Entry Time.
Press [OK] to save and exit or press [MENU] to exit without
saving.
System > Timers >
Entry Time 2
MENU 7-2-2
0
4
0
(*** System Wide Parameter ***)
SECONDS
This menu sets the entry time delay for zones programmed as
entry delay 2 zones. Entry Time 2 is common for all areas on
the system.
When a zone programmed as Delay 2 is triggered, the entry
time will start and the keypad will sound an entry warning
tone. Entry Time 2 can be programmed between 0 and 255
seconds.
Press [MENU] + [7] + [2] + [2]. The keypad will display the
current entry time.
Entry Time 2
040 Seconds
Press 0-9 OK to SAVE
Using the numeric keys, enter the required delay for Entry Time
2 in seconds. Valid times are 0 - 255 seconds 0 = No Entry Time.
Press [OK] to save and exit or press [MENU] to exit without
saving.
1)
2)
3)
1)
2)
3)