9-13
Comms > Comms Test >
Test Route
MENU 5-9-4
0 = Report Events To Log Only
1
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
This menu programs which destination will be used to send
both manual and automatic test reports.
(*** System Wide Parameter ***)
Press [MENU] + [5] + [9] + [4]. The keypad will display the
current Test Route.
Test Route
01-Dest 1 + Log
Press 0-9 OK to SAVE
Use the up and down arrow keys to select the Test Route
required then Press [OK] to save and exit or press [MENU] to
exit without saving.
Comms > Comms Test >
Dial Number Test
MENU 5-9-5
This option provides a quick and easy way for the Installer
to test the communication path for the panel while they are
onsite without the need to trigger test reports and then verify
them with the base station. Once the telco wiring has been
completed, enter your mobile phone or another test number
into this location and press [OK]. The panel will then seize the
phone line and dial the programmed number.
Press [MENU] + [5] + [9] + [5].
Use the numeric keys to enter the the test number. You can
change a single digit in the number by scrolling the cursor left
or right. For special characters (eg. , = pause * or # etc), use the
up and down arrow keys. To clear all text from the cursor
position to the right, press the [OFF] key.
Enter Digits To Dial
Press
0-9 OK to SAVE
Press [OK] when finished to start the test.
i
Note
The panel will make only one attempt to call this number per
activation. To perform multiple tests repeat the sequence. There
is no need to answer the test call.