7-6
Basic parameterization
REFUspeed RS51
DOK-RD500*-RS51*******-IB02-EN-P
t
0 %
-100%
100%
Setpoint
RFG output
Ramp-up
time
Ramp-
down
time
Direction of
rotation reversal
Ramp-up
time
Ramp-
down
time
Fig. 7-3: Up and down ramps
7.4
Guided parameterization
Drive control / setpoints
Pa-
rameter
No.:
Name
Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0870
On/off for NORMAL
Enters On/off for NORMAL operation
0
=
Term. steady-st. (steady-st.
corr. to a switch function)
1
=
T. stat.+OP(T=terminals
OP=operator panel)
2
=
T. stat.+PC (PC w/ RE
FUwin via service-
interface)
3
=
T. stat.+bus SS1
(SS = serial interface)
4
=
T. stat.+bus SS2 (if
available)
5
=
T. stat.+bus SS4 (if
available)
6
=
T. dyn. (OFF always)
(dyn.=dynamic)
7
=
OP dyn. (OFF always)
8
=
T. dynamic (dynamic
corr. to a pushbutton funct.)
9
=
OP dynamic
10
=
OP static
11
=
T. stat.+bus SS6
Terminal dynamic
0...11
1