6-2
Operator control and visualization
REFUspeed RS51
DOK-RD500*-RS51*******-IB02-EN-P
Key
Function
Conditions
Start
Starts the drive
Stop
Stops the drive
The On/Off command must be set to
“Terminal steady-state + operator panel”
or “Operator panel, dynamic”; refer to
Section 5.4.1, Drive control/setpoints.
Motorized potentiometer:
Increases the setpoint
or
increases the Active Load
Monitor (ALM) sensitivity
Motorized potentiometer:
Decreases the setpoint
or
reduces the Active Load
Monitor (ALM) sensitivity
Motorized potentiometer setpoint:
The setpoint must be set to “Motorized
potentiometer”; refer to Section 5.4.1,
Drive control /setpoints.
or
active load monitor sensitivity - motor-
ized potentiometer up / down:
The setpoint may not be set to “Motor-
ized potentiometer”; refer to Section
5.4.1 Drive control /setpoints.
+
Toggles between the
NORMAL and TEST
modes
Password level 2 must be selected and
the inverter must be inhibited (refer to
Section 4.2.2, Operating display).
Fig. 6-2: Function of the operator panel in “Operation”
Normal and test operation (local / remote)
The two operating modes are intended for setting-up or for service pur-
poses (test mode) and for normal operation (normal mode). The On/Off
commands and the setpoint input can be separately set for each mode.
For example, the normal mode can be set-up for terminal operation
(P0870 = terminal, steady-state) and the test mode for operator control
using the operator panel (P0871 = operator panel, steady-state).
Monitoring (monitor) using the operator panel
Key
Menu levels
Esc
Return jump to the previous menu item
Mon
Change into the monitor
Prog
Change in the parameterization
Enter
Accept the selected menu item
To the previous menu item
To the next menu item
Fig. 6-3: Key functions of the operator panel in the monitor mode