REFUspeed RS51
Electrical installation
5-19
DOK-RD500*-RS51*******-IB02-EN-P
5.9
Standard SS6 interface (X13)
Note:
Only for internal use.
5.10 Standard terminal assignment of the REFU
speed
RS51
Recommended terminal assignment with good compatibility to the
REFU 316F
For this recommended assignment, a KL17037 must be inserted at option
slot 2.
Note:
This means, that there is only 1 option slot available for other
modules!
REFUspeed RS51
REFU 316 F
Function
Terminal Designation
Module
Terminal Module
X11
SR17000
X16
IO4004
Operator panel
X11
SR17000
-
-
RS232 service interface
-
-
X21
RS4012
RS232 interface
X12
SR17000
-
-
RS485 interface
X14.1
SR17000
X2.32
Terminal
24V / 50mA control voltage output
X14.7
SR17000
X2.
0V digital reference point
X17.1
SR17000
X2.11
Terminal
15V / 50mA control voltage output
X17.8
SR17000
X2.48
Terminal
0V digital reference point
X14.2
Dig In/Out 1
SR17000
X56.11/1
2
WM4034
Dig. output for WM signal
“Sparking” signal
or signal “Load limit”
X14.3
Dig In/Out 2
SR17000
Motpot. active load monitor sensitivity up /
(can be freely configured)
X14.4
Dig In/Out 3
SR17000
Motpot. active load monitor sensitivity down
/ (can be freely configured)
X14.5
Dig In 4
SR17000
X2.10
Terminal
Par. set selection, weighting 2
4
X14.6
Dig In 5
SR17000
X2.9
Terminal
External fault acknowledgement
X17.2
Dig In 6
SR17000
X2.33
Terminal
Start NO contact
X17.3
Dig In 9
SR17000
X2.13
Terminal
Par. set selection, weighting 2
1
X17.4
Dig In 7
SR17000
X2.31
Terminal
Stop NC contact
X17.5
Dig In 10
SR17000
X2.14
Terminal
Par. set selection, weighting 2
2