Note: For a MIC camera, physical alarm connections are only applicable when the camera is
connected to optional MIC-ALM-WAS-24 or VJC-7000-90.
Alarm Inputs
Select the type of input for each physical alarm. Select from either N.O. (Normally Open) or
N.C. (Normally Closed) and provide an optional name for each input.
Alarm Outputs
The camera incorporates three (3) open collector alarm or transistor outputs. Use the
following settings to configure the relay for alarm outputs.
Idle state
Specify either Open or Closed idle state.
Operating mode
Select one of the following modes for operation: Bistable, 0.5 s, 1 s, 5 s, 10 s, or 60 s.
Output name
Type an optional name for the relay connection, up to 20 characters.
Trigger output
Click the appropriate Trigger output button to test the relay / output connection.
Advanced Mode: Network
Network Access, page 79
DynDNS, page 81
Advanced, page 82
Network Management, page 83
Multicast, page 83
Image Posting, page 84
Accounts, page 85
IPv4 Filter, page 86
Encryption, page 86
Network Access
The settings on this page are used to integrate the camera into an existing network.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
1.
Make the desired changes.
2.
Click the Set and Reboot button. The camera reboots and the changed settings are
activated.
!
Caution!
If you change the IP address, subnet mask or gateway address, the camera is only available
under the new addresses after the reboot.
Automatic IP assignment
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you
can activate acceptance of IP addresses automatically assigned to the camera.
Certain applications (Bosch Video Management System, Archive Player, Configuration
Manager) use the IP address for the unique assignment of the unit. If you use these
applications, the DHCP server must support the fixed assignment between IP address and
MAC address, and must be appropriately set up so that, once an IP address is assigned, it is
retained each time the system is rebooted.
15.39
15.40
15.41
15.42
MIC IP starlight 7000 HD, MIC IP
dynamic 7000 HD
Configuration via IP, Advanced Mode | en
79
Bosch Security Systems
Operation Manual
2014.09 | 1.3 | F.01U.291.520
Содержание MIC-71 series
Страница 1: ...MIC IP starlight 7000 HD MIC IP dynamic 7000 HD MIC 71xx MIC 72xx en Operation Manual ...
Страница 2: ......
Страница 110: ......
Страница 111: ......