![Bosch K2200 Series Скачать руководство пользователя страница 49](http://html.mh-extra.com/html/bosch/k2200-series/k2200-series_user-manual_39361049.webp)
K2200 Series |
User Guide | 6.0
Installer Commands
EN
| 49
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
6.2.5
Relay Programming
- The RE Command: There are two types of relay
that can be activated. They are:
•
The 4 relays located on each door controller.
•
The 4 relays located on each alarm module.
The relays on the alarm modules can be activated by
alarm module Inputs as described above, in the MS
command. This section describes how to use both
these types of relay to respond to other events
There are two types of event to which these relays
can respond; system events and time profiles. It is
unlikely that you will activate a relay on both a
system event and time profile, however, it is possible
- the relay will stay set until all conditions are clear.
System Events
The following table shows the types of event and
their code number that can be assigned to a relay.
Table 24: Event Types
System
Event
Relay
Code
Notes:
No Response
0
Door Alarm on
any door
1
An alarm event (i.e.
unauthorized access, cable
tamper, etc.) at any of the four
doors on the door controller
will activate a relay given this
code. The relay will not be
deactivated until all such
alarms are cleared. This is the
same as the default action
given to relay 1 if not
programmed otherwise.
Door Left
Open on any
door
2
This code will activate a relay
if any of the four doors on the
door controller are left open
and it will be deactivated
when all the doors are closed.
This is the same as the default
action given to relay 3 if not
programmed otherwise
Case Tamper
3
Door 1 Open
4
Door 2 Open
5
Door 3 Open
6
Door 4 Open
7
These codes will activate a
relay if the particular door is
opened for any reason. It will
deactivate when the door is
closed.
Door 1 Left
Open
8
Door 2 Left
Open
9
Door 3 Left
Open
10
Door 4 Left
open
11
These codes will activate a
relay if the particular door is
left open and it will deactivate
when the door is closed
Door 1 Alarm
12
Door 2 Alarm
13
Door 3 Alarm
14
Door 4 Alarm
15
These codes will activate a
relay if the particular door has
an alarm event, i.e.
unauthorized access or cable
tamper, and it will deactivate
when the alarm is cleared
Time Profiles
A relay can be made to operate with a time profile.
When the time profile is active, the relay will be set.
Examples are the use of external lighting, switching
heating or ventilation systems, etc.
Using the RE Command
There are 16 relay records, one for each alarm
module.