![Bosch K2200 Series Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/bosch/k2200-series/k2200-series_user-manual_39361037.webp)
K2200 Series |
User Guide | 5.0
Displays, Alarms, and Printing
EN
| 37
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Table 16: System Status – Doors and Alarm Zones
System Parameter
Display Message
Description
UNLOCKED
Door is manually or automatically unlocked, see Override
LOCKED
The door requires a valid key
Doors
Door States
OPEN
The door is physically open
NO ALARM
No alarm conditions present
TAMPER/FORCED
A Tamper or Unauthorized Access
Door Alarm States
LEFT OPEN
Door left open
YES
If doors all doors opened,
Emergency Override?
NO
Normal condition.
NORMAL
No override active
UNLOCK
Door manually unlocked (L Command)
Manual Override?
LOCKED
Door manually locked (L Command)
YES
Door opened on a time profile
Timed Override?
NO
No active time profile
Alarm Zone States - Only alarm module Inputs that have been assigned responses are shown.
YES
Isolated, either manually or by a time profile
Isolated?
NO
Zone is active
CLEAR
Input is in its normal condition
State
ALARM
Input is in alarm state
Figure 16: Sample P4 - System Status Printout
Readykey K2200 DOOR AND ALARM STATUS REPORT
DATE: 11-11-93 TIME: 10:24 REQUESTED BY MASTER KEY PAGE 1
DOOR CONTROLLER : 01
DOOR DOOR NAME STATE ALARM STATE EMERGENCY MANUAL TIMED
OVERRIDE? OVERRIDE? OVERRIDE?
01 FRONT DR IN UNLOCKED NO ALARM NO NORMAL YES
02 ACCOUNTS OPEN FORCED/TAMPER NO NORMAL NO
03 SALES RECEP LOCKED NO ALARM NO NORMAL NO
04 FRONT DR OUT UNLOCKED NO ALARM NO NORMAL NO
ALARM ZONE STATUS
ZONE NO ISOLATED? STATE
1 YES INPUT CLEAR
2 YES INPUT CLEAR
P5 – Transaction Printout
The
P5
command prompts you for a date and time range.
Note:
The printout will give all the high priority transactions that have occurred in the date range first, followed by the rest of
the transactions. This may result in a pause between the two parts of the report.