K2200 Series |
User Guide | 6.0
Installer Commands
EN
| 46
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
6.2
Alarm Event Manager and Relay
Outputs
6.2.1
Overview
The Alarm Event Manager is an optional alarm
module that can be attached to any reader channel. It
can be attached at any point in the cable between the
door controller and reader. The alarm module has 8
inputs and 8 relay outputs
but relays 5 to 8 can only
administrated by Readykey for Windows
.
8 Monitored Inputs
Each alarm module can monitor up to 8 inputs and
generate an alarm if any enabled input is activated.
Each input may be:
•
Normally Open or Normally Closed (set on the
module itself)
•
Enabled/Disabled Manually
•
Enabled/Disabled using a time profile
•
Programmed to activate a relay.
8 Relay Outputs
The 8 relay outputs on the module may be activated
by:
•
An monitored input being activated.
•
A system event.
•
A time profile.
6.2.2
Identiying Modules, Inputs and Relays
Each reader channel on a door controller may have
an alarm module connected. This means a maximum
of 16 modules per system (four on each door
controller, although only two on a Readykey K1200).
Each alarm module has 8 possible inputs. These are
numbered 1 to 8 on each alarm module. When
reporting, however, the zone number, 1 to 128, is
used. The zone number is as shown in the following
table.
Table 21: Zone Number
Zone Numbers
Input Number:
Location
1
2
3
4
5
6
7
8
Door Controller 1
Alarm Module 1
1
2
3
4
5
6
7
8
Alarm Module 2
9
10
11
12
13
14
15
16
Alarm Module 3 *
17
18
19
20
21
22
23
24
Alarm Module 4 *
25
26
27
28
29
30
31
32
Door Controller 2
Alarm Module 5
33
34
35
36
37
38
39
40
Alarm Module 6
41
42
43
44
45
46
47
48
Alarm Module 7 *
49
50
51
52
53
54
55
56
Alarm Module 8 *
57
58
59
60
61
62
63
64
Door Controller 3
Alarm Module 9
65
66
67
68
69
70
71
72
Alarm Module 10
73
74
75
76
77
78
79
80
Alarm Module 11 *
81
82
83
84
85
86
87
88
Alarm Module 12 *
89
90
91
92
93
94
95
96
Door Controller 4
Alarm Module 13
97
98
99
100
101
102
103
104
Alarm Module 14
105
106
107
108
109
110
111
112
Alarm Module 15 *
113
114
115
116
117
118
119
120
Alarm Module 16 *
121
122
123
124
125
126
127
128
* Not available on Readykey K1200