68
en | Technical Specifications
MAP 5000
2019-09 | 25 | F.01U.168.332
Installation manual
Bosch Security Systems B.V.
7
Technical Specifications
Electrical
Maximum operating voltage in VAC
230 (-15 %, + 10%)
Minimum AC line frequency in Hz
47
Maximum AC line frequency in Hz
63
Maximum power consumption in W per
power supply
150
Minimum battery capacity in Ah per power
supply
18
Maximum battery capacity in Ah per power
supply
80
Back‑up time
Determined by battery capacity and system
load. Consider time or capacity limits for
recharging the batteries regarding local
regulations or EN standards if needed.
Refer to , page 21 for the location of the ratings label on the power supply.
Frequency bands of operation
Power level for radio equipment
GSM900
Class 4 (2W) - GPRS Class 10
GSM1800
Class 1 (1W) - GPRS Class 10
Mechanical
Panel enclosure
Dimension in cm (H x W x D)
65.8 x 44.3 x 19.35
Weight in g
1566
Power enclosure
Dimension in cm (H x W x D)
65.8 x 44.3 x 19.35
Weight in g
1566
Expansion
enclosure
Dimension in cm (H x W x D)
43.6 x 44.3 x 11.2
Weight in g
780
System parameters
Number of addresses
1500
Number of areas
500
1
Event log capacity
4000
Users
Number of users
1000
Содержание ICP-MAP5000-2
Страница 1: ...MAP 5000 ICP MAP5000 2 ICP MAP5000 COM ICP MAP5000 S ICP MAP5000 SC en Installation manual ...
Страница 2: ......
Страница 87: ...MAP 5000 Appendices 87 Bosch Security Systems B V Installation manual 2019 09 25 F 01U 168 332 ...
Страница 88: ...88 Appendices MAP 5000 2019 09 25 F 01U 168 332 Installation manual Bosch Security Systems B V ...
Страница 89: ......