en | Connections
MAP 5000
2019-09 | 25 | F.01U.168.332
Installation manual
Bosch Security Systems B.V.
!
Warning!
Remove the protective dust cover label from the top of the power supply.
3.11
IP Interface
Ethernet connector
CAT5e
Ethernetkabel
(max. 100m)
Ethernet-
connector
RJ 45
PC
BIS
Ethernet-
connector
RJ 45
Ethernet cable type: CAT5e
VdS and EN50131: The usage of the MAP 5000 Ethernet interface is permitted if the
following conditions are met.
1.
Use a direct connection (1:1 connection) for connecting the management system to
MAP5000.
2.
When using repeaters (switches), ensure that no other network components are
connected to the repeaters.
3.
For operation of the management system, restrict the data transfer from MAP5000 to the
management system. Ensure that this does not have any influence on the panel.
VdS and EN50131 programming instruction
Settings in
RPS for MAP
:
4
In the MAP5000 panel menu, select ->
setup: Management system as a Monitoring
Station
.
Notice!
Data transfer between the MAP 5000 and the connected PC system must always take place
via a secure, authenticated and encrypted connection.