Page 7 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
3.2
Water connections
Requisite
Observations
Confirmation
Water pipes were cleaned before
connected to the appliance?
Leakage test was done
successfully?
Inlet water filter was checked and is
cleaned, ensuring the necessary
water flow?
Accessories for water connections
are adequate?
Water pressure and flow are
according to the appliance
specifications?
- Nominal pressure: 300 - 700 kPa
- Minimum pressure: 100 kPa
- Maximum pressure: 1000kPa
Table 5 – Check list hydraulic connections
3.3
Gas connection
Requisite
Confirmation
The appliance is suitable for the available gas type?
Pressure reducer and gas pipe are adequate for the required pressure and
gas flow?
Accessories for gas connection are adequate and according to the country
specification/standards?
Table 6 – Check list for gas connections
Pict. 7 – Manometer pipe connection to measure static/dynamic gas supply pressure
(showing indoor version)
3.4
Appliance performance
Measure water flow and temperature increase to check temperature and instantaneous water flow, assuring
correct operation of the appliance.
Gas
manometer