Insufficient air flow at start up
Software Version AF1112
Lockout / shutdown of burner
(self reset by closing water)
Software Version AF1113
Lockout / shutdown of burner
(manual reset required)
C5
Bypass valve damaged or disconnected.
Warning
(only if bypass valve is activated)
Note: error only existing in outdoor
GWH16/20/26
C7
Fan unplugged / no detection of rotation/speed signal
from fan
Lockout
(reset by closing water)
CA
Water flow signal over specified maximum value (flow >
25 l/min)
Warning
(self reset by reducing water flow)
CF
Blocked exhaustion / Combustion failure
Software Version AF1112
Lockout / shutdown of burner
(self reset by closing water)
Software Version AF1113
Lockout / shutdown of burner
(manual reset required)
E0
Control Unit damage:
Ionization circuit test fault / Software error
Lockout
(manual reset)
E1
Over-temperature detected in hot water outlet sensor (T
out
> 85ºC)
Warning Lockout
(Self-Reset when T < 60ºC)
E2
Inlet water NTC temperature sensor defected (open or
short circuit)
Warning
(self reset when conditions corrected)
E4
Air Box NTC temperature sensor protection by over
temperature detection (T
air
> 80ºC)
Lockout
(manual reset)
E9
Thermo fuse opened circuit (overheat – T=114ºC)
Lockout
(manual reset)
EA
No ionization detected during safety time (safety time
with 3 + 3 trials elapsed)
Lockout
(manual reset)
EC
Ionization failures during operation (loss of ionization 5
times in short period of time)
Software Version AF1113
Lockout
(manual reset)
EE
Modulating Solenoid disconnected
Self reset when solved
EF
High Output (wrong gas type)
Lockout
(manual reset)
F7
Ionization error (flame sensing during stand-by)
Lockout
(manual reset)
FA
Leakage error on gas valve when ionization is detected
after demand finish
Lockout
(manual reset)
FC
Buttons pressed more than 30 sec
Self-reset when button released
F9
Safety Solenoid disconnected
Lockout
(manual reset)
Table 37 – Error code list