CA
Excessive water flow (over specified value > 25 l/min)
Characteristic: Water flow sensor (turbine)
Warning Message
Appliance keeps operation and code is flashing
Brown
– Blue: 0 – 45 V dc
Orange
– Blue: 10.8 – 13.2 V dc
Yellow
– Blue: pulse frequency
Defective Fan
No signal from control unit to
fan?
Defective Control Unit
Replace Control Unit
Replace Fan
No
Yes
Excessive water flow through
water heater
Water pressure
excessive
Water flow signal > 172.5 Hz
Yes
No
Refer to table in service
manual with color code / flow
per model and correct it.
End
Remove inlet water
connection and check
existence of water flow
restrictor / filter
Problem solved?
No
Check need for water
pressure reducer valve