Page 51 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
Cleaning the filter
For the cleaning of the filter, first loose the clip (2), than remove the cover (3) that is fixed
in the body of water valve – see picture 38. Pull the water flow restrictor with integrated
filter from the front to the outside of the water assy. Clean the filter with water and / or air
pressure and assemble it back on the water.
Pict.51 – Water filter removal (low / high output range)
Inspect and clean the heat exchanger when needed. To remove the heat exchanger,
isolate the appliance from incoming cold water supply at the inlet cock. Open the taps to
release any remaining water pressure and drain the appliance over the water assy cover -
(3) in picture 38.
Pict.52 – Heat exchanger cleaning