Page 44 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
Step 4
-
If the problem persists disconnect the appliance, wait at least 30 seconds, connect it
again and retry the connection;
-
Restart as well the smartphone and open again the app and repeat the procedure for
pairing unit with smartphone;
Attention:
Important Information for Technicians when replacing Control Unit:
-
The function of data backup must be used without disconnecting the app and following
this procedure:
1
st
– Press “backup” to read info (configuration parameters) from Control Unit;
2
nd
– Disconnect power supply and replace control unit changing Bluetooth dongle for new
ECU;
3
rd
– Turn On unit and search again for devices on the App and perform the connection;
4
th
– Press “restore” to upload configuration data in new ECU.
Diagnostic Mode
The access to the data visualization mode, is made by entering first in the “service mode”
and then, scrolling to the parameter “P4” of the adjustment mode.
Diagnostic mode and
visualization mode
Installer Level
Technician Level
Comments
This mode helps the
installer in the startup
to check parameters
such as water flow
through the appliance
and inlet / outlet
temperatures
This mode helps the
technician to find some
information useful to
adjust and to check
functionality of the
appliance.
Main recommendation is
to perform always a check
on the last 10 failures in
memory in order to
analyze eventual
problems in installation
that might need to be
corrected
Table 28 – P4
By pressing the “P” button while the display shows “P4”, the LCD will enter into
visualization mode and will show “E”, meaning “Exit” from the visualization mode. By