Page 48 from 76 6 720 814 719
SM FP_Australia 2017/04 EN
To change the gas type, enter first into the service mode and then scroll to the parameter
“P7”. This parameter allows the control of the modulation range according to the gas type.
In order to ensure a proper operation of the appliance, this parameter must be checked
when the control unit is replaced.
Appliance Type selection
Settings:
Comments
AU settings
20 – Natural Gas G20
31 – Propane G31
Not used settings:
30 – Butane G30
25 – Natural Gas G25
28 – natural Gas G20
(with injectors of 1.8)
NG models will have
from factory 20
LPG models will have
from factory 31
Note: spare part pre-set value
is 20
Table 32 – P7
Backlight activation
Default Value
Possible
Selection
Comments
dE
(deactivated)
ON
Allows the activation of the
backlight of the LCD
Not Available for AU/NZ
Table 33 – P8
Purge mode
Comments
This activates the fan and cool down the appliance (heat cell)
Table 34 – P9
The following parameter is only applicable when correspondent component is replaced in field.