background image

Model Numbers

MH-45-KFA / MH-75T-KFA / MH-135T-KFA / MH-190T-KFA / MH-215T-KFA

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

GENERAL HAZARD WARNING: READ AND UNDERSTAND 

ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE 

ASSEMBLING, STARTING, OR SERVICING THE HEATER. 

Be sure to comply with the instructions and warnings provided with this heater. Failure to 

comply can result in fire or explosion that can cause property loss, bodily injury, or loss 

of life. Only persons who can follow and understand these instructions should operate or 

service this heater. If you need heater info; such as an operating manual, labels, etcetera, 

contact Pinnacle Climate Technologies at 800-779-3267.

DANGER

NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN 

ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION. 

FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY 

FOR:

 

THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS 

OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. 

This is an 

unvented portable heater that uses air (Oxygen) from within the area in which it is used.  

Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon 

monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 5.

FACTORY ID: 001

Safety Information

FIRE, BURN, INHALATION AND EXPLOSION HAZARD. 

Keep 

combustibles such as; building materials, paper or cardboard a 

safe distance away from the heater as recommended by these 

instructions. Never use the heater in spaces which contain products such as; gasoline, 

solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown 

chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which 

it is used. Adequate combustion and ventilation air must be provided. Refer to “Ventilation” 

on page 5. Bulk fuel storage should be a minimum of 25 feet (7.6 m) from heater.

WARNING

DO NOT OPERATE THIS HEATER UNTIL 

YOU HAVE READ AND THOROUGHLY 

UNDERSTAND THESE SAFETY AND 

OPERATING INSTRUCTIONS.

Failure to comply with the precautions and instructions provided with this 

heater can result in death, serious bodily injury, property loss or damage 

from the hazards of fire, soot production, explosions, burns, asphyxiation or 

carbon monoxide poisoning. Only persons who can read and understand 

these instructions should use or service this heater

DANGER

WARNING

1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (800) 779-3267

Fax: 320-251-2922 • Web: www.masterindustrialproducts.com • Email: [email protected]

© 2017 Pinnacle Climate Technologies, Inc. MAKB-400

User’s Manual & 

Operating Instructions

KEROSENE FORCED AIR 

HEATER

Содержание MH-135T-KFA

Страница 1: ... 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instructions Never use the heater in spaces which contain products such as gasoline solvents paint thinners dust particles volatile or airborne combustibles or any unknown chemicals This is an unv...

Страница 2: ...e for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 combustion efficiency but does produce small amounts of carbon monoxide Carbon monoxide is toxic Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide ...

Страница 3: ... Combustibles 45 190T KFA 215T KFA Top 4 ft 125 cm 4 ft 125 cm Sides 4 ft 125 cm 4 ft 125 cm Front 8 ft 250 cm 10 ft 305 cm ALWAYS locate heater on a stable and level surface If your heater is equipped with a thermostat once it is plugged in it can start at anytime in accordance with the thermostat setting RISK OF BURNS FIRE AND EXPLOSION RISK OF ELECTRIC SHOCK CAUTION HOT WHILE IN OPERATION DO NO...

Страница 4: ...s Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 13 mm Screws 2 Figure 3 Figure 4 ...

Страница 5: ...e heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and wheel support frame and tighten firmly 6 Insert 2 short screws 30 mm through the first hole from the front in the tank lip and tighten firmly Make certain all 4 screws are secure 7 Attach rear handle with...

Страница 6: ... heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene in a red container Red is associated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater o...

Страница 7: ...m temperature display will indicate the following When the temperature is less than 0 ºF the display says LO When the temperature is more that 99 ºF the display says HI Between 0 F and 99 F the display shows actual temperature Stopping Restarting Heater To stop the heater move the power switch to the Off position and unplug the power cord To restart the heater wait 10 seconds and follow ignition s...

Страница 8: ... starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 75T KFA turn filter 90º clockwise To remove the filter from models 125T 215T KFA turn filter 90º counter clockwise See Figure 3 T...

Страница 9: ...heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 75T KFA 4 2 PSI 0 29 BAR 135T KFA 5 5 PSI 0 38 BAR 190T KFA 8 5 PSI 0 59 BAR 215T KFA 9 0 PSI 0 62 BAR Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fue...

Страница 10: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerosene 7 Inspect all electrical connections See wiring diagrams on page 3 8 Re attach ignitor wire to spark plug 9 Replace ignitor 10 Adjust rotor Fan does not operate when heater is plugged in and power...

Страница 11: ...A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 39 34 42 Exploded View 10 45 KFA 75T KFA Only 135T KFA 215T KFA Only ...

Страница 12: ... 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 21 Filter Kit 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 22 End Filter Cover 70 020 0103 70 020 0103 70 020 0103 70 020 0103 70 0...

Страница 13: ...d If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for products that are purchased from sellers other than authorized dealers or distributors AFTER THE PERIOD OF THE ONE 1 YEAR E...

Страница 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc ...

Отзывы: