background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

2

Safety Information

ALWAYS use only the electrical power (voltage and 

frequency) specified on the model plate of the heater.

ALWAYS use only three-prong, grounded outlet and 

extension cord. 
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.  
ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or wind.

NEVER use fuels such as gasoline, benzine, paint 

thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the 

heater is operating or still hot. This heater is 

EXTREMELY HOT while in operation. 
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.

NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.

Keep all combustible materials away from this heater. 

Minimum Clearance From Combustibles

45-190T-KFA

215T-KFA

Top

4 ft. (125 cm)

4 ft. (125 cm)

Sides

4 ft. (125 cm)

4 ft. (125 cm)

Front

8 ft. (250 cm)

10 ft. (305 cm)

ALWAYS locate heater on a stable and level surface. 
If your heater is equipped with a thermostat, 

once it is plugged in, it can start at anytime in 

accordance with the thermostat setting. 

RISK OF BURNS, 

FIRE AND 

EXPLOSION!

RISK OF 

ELECTRIC 

SHOCK!

CAUTION! 

HOT WHILE IN 

OPERATION. 

DO NOT TOUCH. KEEP CHILDREN, 

ANIMALS, CLOTHING AND 

COMBUSTIBLES AWAY FROM HEATER. 

WARNING

WARNING

WARNING

Specifications

Model #

45-KFA

75T-KFA

135T-KFA

190T-KFA

215T-KFA

Rating: Btu/Hr / kW

45,000 / 13.19 75,000 / 21.98 135,000 / 39.56 190,000 / 55.68 215,000 / 63.01

Fuel Consumption: Gal/Hr / L/Hr

0.35 / 1.32

0.56 / 2.12

1.00 / 3.79

1.42 / 5.38

1.63 / 6.17

Fuel Tank Capacity: Gallons / Liters

5 / 19

5 / 19

10 / 38

13 / 49

13 / 49

Pump Pressure: psi / BAR

3.0 / 0.21

4.2 / 0.29

5.5 / 0.38

8.5 / 0.59

9.0 / 0.62

Volts: AC/Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

120VAC / 60Hz

Amps

1.4

1.5

2.3

2.7

2.8

Phase

Single

Single

Single

Single

Single

Specifications subject to change without notice.

Locating Your Serial Number:

Your serial number can be found on a white label on the right side cover of your heater. For Example: 

150812779. Have your Serial Number ready before calling customer service at 800-779-3267.

Содержание MH-135T-KFA

Страница 1: ... 5 FACTORY ID 001 Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instructions Never use the heater in spaces which contain products such as gasoline solvents paint thinners dust particles volatile or airborne combustibles or any unknown chemicals This is an unv...

Страница 2: ...e for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 combustion efficiency but does produce small amounts of carbon monoxide Carbon monoxide is toxic Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide ...

Страница 3: ... Combustibles 45 190T KFA 215T KFA Top 4 ft 125 cm 4 ft 125 cm Sides 4 ft 125 cm 4 ft 125 cm Front 8 ft 250 cm 10 ft 305 cm ALWAYS locate heater on a stable and level surface If your heater is equipped with a thermostat once it is plugged in it can start at anytime in accordance with the thermostat setting RISK OF BURNS FIRE AND EXPLOSION RISK OF ELECTRIC SHOCK CAUTION HOT WHILE IN OPERATION DO NO...

Страница 4: ...s Manual 3 Wiring Diagrams 45 KFA 75T 215T KFA Assembly Instructions What s In The Box Models 45 KFA 75T KFA Remove the heater and all packaging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 13 mm Screws 2 Figure 3 Figure 4 ...

Страница 5: ...e heater on wheel support and line up holes on the fuel tank lip 5 Attach front handle with 2 long screws 50 mm and 2 nuts through the second hole from the front on both sides of the tank lip and wheel support frame and tighten firmly 6 Insert 2 short screws 30 mm through the first hole from the front in the tank lip and tighten firmly Make certain all 4 screws are secure 7 Attach rear handle with...

Страница 6: ... heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene in a red container Red is associated with gasoline Ventilation Risk of indoor air pollution and Carbon Monoxide Poisoning Use heater o...

Страница 7: ...m temperature display will indicate the following When the temperature is less than 0 ºF the display says LO When the temperature is more that 99 ºF the display says HI Between 0 F and 99 F the display shows actual temperature Stopping Restarting Heater To stop the heater move the power switch to the Off position and unplug the power cord To restart the heater wait 10 seconds and follow ignition s...

Страница 8: ... starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 75T KFA turn filter 90º clockwise To remove the filter from models 125T 215T KFA turn filter 90º counter clockwise See Figure 3 T...

Страница 9: ...heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 75T KFA 4 2 PSI 0 29 BAR 135T KFA 5 5 PSI 0 38 BAR 190T KFA 8 5 PSI 0 59 BAR 215T KFA 9 0 PSI 0 62 BAR Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fue...

Страница 10: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh kerosene 7 Inspect all electrical connections See wiring diagrams on page 3 8 Re attach ignitor wire to spark plug 9 Replace ignitor 10 Adjust rotor Fan does not operate when heater is plugged in and power...

Страница 11: ...A POWER SOURCE 2017 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 14 11 13 8 12 9 30 26 3 16 2 4 6 1 7 22 24 17 18 19 21 30 20 15 41 33 35 36 29 28 5 32 31 25 27 38 37 39 34 42 Exploded View 10 45 KFA 75T KFA Only 135T KFA 215T KFA Only ...

Страница 12: ... 0510 70 021 0520 70 021 0520 18 Pump Body 70 020 0101 70 020 0101 70 020 0101 70 020 0401 70 020 0401 19 Rotor Kit 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 20 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 21 Filter Kit 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 22 End Filter Cover 70 020 0103 70 020 0103 70 020 0103 70 020 0103 70 0...

Страница 13: ...d If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Climate Technologies Inc disclaims all warranties for products that are purchased from sellers other than authorized dealers or distributors AFTER THE PERIOD OF THE ONE 1 YEAR E...

Страница 14: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc ...

Отзывы: