6 720 817 281 (2017/05)
Greentherm 9800 SEO 160/199 | SECO 199
Problem solving | 41
E8
Error during ionization test. Electronic control unit
internal error.
▶ Replace electronic control unit.
E9
Thermal fuse [13] broken.
▶ Replace thermal fuse.
EA
Ignition failure.
▶ Check gas inlet pressure (
section 6.6).
▶ Perform gas and air tuning (
section 10.11).
EC
Flame lost during operation.
▶ Check gas inlet pressure (
section 6.6).
▶ Perform gas and air tuning (
section 10.11).
EE
Gas valve modulation solenoid [7] disconnected.
▶ Check gas valve wire connection.
If the problem persists:
▶ Replace the gas valve and/or wire connections and/
or electronic control unit. For gas valve replacement
perform gas and air tuning (
EF
Wrong gas connected (LP instead of NG) for
current appliance configuration.
▶ Check gas type (
section 3.3).
F2
Electronic control unit internal error.
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
F3
Electronic control unit internal error.
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
F7
Electronic control unit internal error.
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
F8
Electronic control unit internal error.
▶ Reset error (press and hold on/off button for 3
seconds).
If the problem persists:
▶ Replace electronic control unit.
F9
Gas valve driver internal fault.
▶ Check gas valve wire connections.
If the problem persists:
▶ Replace the wire connections and/or electronic
control unit.
FA
Gas leakage in the gas path (gas valve or gas
manifold shut-off valves).
▶ Replace the gas valve and/or gas manifold.
▶ After gas valve and/or gas manifold replacement
perform gas and air tuning (
Display shows
SOLAR
but without
existence of solar
thermal system.
Power demand lower than appliance minimum
output power.
▶ Increase hot water flow.
▶ increase setpoint temperature.
Display shows
SOLAR
and water
temperature low.
Display
Description
Solution
Table 20