6 720 817 281 (2017/05)
Greentherm 9800 SEO 160/199 | SECO 199
Installation instructions | 13
4.4
Selecting heater location
▶ Choose an outside wall for the installation. Installation on a
wall protected by an overhang above is recommended.
▶ Install the water heater above anticipated snow level.
Minimum clearances
If the appliance is installed under an overhang, there must be a
36" clearance from the top of the appliance and the mounting
area must be open in front and on the sides of the appliance.
Fig. 5
4.5
Mounting instructions
▶ The water heater is approved for installation directly on an
outside wall. Secure the wall mounting bracket provided
with the water heater to a wall surface. See fig. 6.
▶ The installation method of the mounting bracket will
depend on the type of mounting surface. Due to the
varieties of building siding or surfacing, the installer must
decide on how best to support and level the heater on an
outside wall. It is recommended that horizontal or vertical
support boards or plywood sheathing (½ " minimum) first
be attached to the wall surface. The heater must be kept
level on the wall surface.
Fig. 6
Installation on wood siding
Ref
.
Description
Min.
distances
A
Directly below or adjacent to an opening;
operable windows, doors and any fresh air
openings
1 ft
B
C
D
From any adjacent wall
1 ft
E
Below a gutter, sanitary pipework, eaves or
overhang
3 ft
F
Above ground
1 ft
G
From a gas meter or gas regulator
3 ft
Table 4
WARNING:
▶ Do not mount heater directly to vinyl
siding. With vinyl siding, a 3½ ' x 4' area
of the siding must first be removed and
then replaced with wood or other non-
plastic material. See fig. 7.