a) Enter name of the CAN-channel.
b) Enter CAN message ID. Check the box, if extended IDs (29 bit) are used.
c) If replacement values are used, specify time-out period and raw value.
d) Check the box, if a multiplexer (row counter) is used.
e) Enter data position, length and format. The matrix table shows the assignment of the bits.
f) Enter a Conversation to get physical values
Conversion to physical values
a) Enter factor (gain) for conversion to physical value.
b) Enter offset for conversion to physical value.
c) Select type of physical value.
d) Select unit of physical value.
e) Enter minimum physical limit of the channel. (for manual setup)
f) Enter maximum physical limit of the channel. (for manual setup)
g) Check the box to automatically adjust the limits of the channel.
Special features
CAN analyzer functionality
This functionality is only available, if a MSA‐Box (I & II) is used to connect the
DDU 8 to the PC. Choose the CAN bus that is connected to the MSA‐Box to dis‐
play the raw value and the converted physical value here.
Automatic creation of online measurement sheets
The CAN channel can be automatically inserted to a measurement sheet. Insert a
name for a new sheet or select an existing sheet from the listbox.
9.2.5
9.2.6
CAN Bus | 9
Bosch Motorsport
DDU 8 Manual
61 / 160
Содержание DDU 8
Страница 1: ...Display DDU 8 Manual V1 2 9 16 2016 ...
Страница 6: ...Onboard Network Concept 3 3 Onboard Network Concept 6 160 DDU 8 Manual Bosch Motorsport ...
Страница 16: ...Mechanical Drawing 6 6 Mechanical Drawing 16 160 DDU 8 Manual Bosch Motorsport ...
Страница 158: ......
Страница 159: ......
Страница 160: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...