▪ Number and complexity of math channels
▪ Number and complexity of conditions
▪ CAN traffic on both CAN lines
▪ Display configuration, especially displaying pictures
▪ Logger configuration (total logging rate [kB/s], conditional measurement
rates)
To help respecting the limit of 85 % CPU load, the DDU 8 creates an error memo‐
ry entry. To trigger this error entry, the CPU load must exceed the limit for 5 mi‐
nutes without interruption.
When being confronted with this error memory entry (see ‘Error info’ in RaceCon)
or when being confronted with DDU 8 resets due to complex configuration set‐
ups, please consider reducing the demands on the DDU 8 adapting the influenc‐
ing factors mentioned above.
Display Configuration | 8
Bosch Motorsport
DDU 8 Manual
57 / 160
Содержание DDU 8
Страница 1: ...Display DDU 8 Manual V1 2 9 16 2016 ...
Страница 6: ...Onboard Network Concept 3 3 Onboard Network Concept 6 160 DDU 8 Manual Bosch Motorsport ...
Страница 16: ...Mechanical Drawing 6 6 Mechanical Drawing 16 160 DDU 8 Manual Bosch Motorsport ...
Страница 158: ......
Страница 159: ......
Страница 160: ...Bosch Engineering GmbH Motorsport Robert Bosch Allee 1 74232 Abstatt Germany www bosch motorsport com ...