PRS-NSP Network Splitter
Use the PRS-NSP Network Splitter to make tap-offs in the optical network that have protection
against short-circuits.
7
8
3
2
1
5
4
6
Figure 3.61: Front, rear and top views
1.
External power supply socket - Connects the network splitter to an external power
supply. The external power supply supplies power to the tap-offs. It does not supply
power to the trunk.
2.
Optical network socket (tap-off 1) - Makes a tap-off in the optical network. The socket
has a maximum load of 2.5 A that gives protection against short-circuits.
3.
Optical network socket (trunk) - Connects the network splitter to the trunk of the optical
network.
4.
Lid - Gives access to the controls inside. The rear side of the lid contains a label with an
explanation about the internal settings.
5.
Status LED - A yellow LED that gives information about the condition of the network
splitter.
6.
Status LED - A green LED that gives information about the condition of the network
splitter.
7.
Optical network socket (tap-off 2) - Makes a tap-off in the optical network. The socket
has a maximum load of 2.5 A that gives protection against short-circuits.
8.
Optical network socket (trunk) - Connects the network splitter to the trunk of the optical
network.
The following sections give more information about the mentioned subject:
–
Installation: PRS-NSP Network Splitter, page 111.
–
Connection: PRS-NSP Network Splitter, page 146.
–
Configuration: PRS-NSP Network Splitter, page 227.
–
Troubleshooting: LBB4114/00 or LBB4115/00 Trunk Splitter, page 266.