DCN-DDB Data Distribution Board
Overview
Configure the data distribution board with the S8 switches.
Switch
Position
Description
S8-1
ON / OFF*
RS232 enabled / RS232 disabled
S8-2
ON / OFF*
Reserved / Passive mode
S8-3
ON / OFF*
19200 baud / 9600 baud
S8-4
ON / OFF*
Reserved
S8-5
ON / OFF*
Reserved
S8-6
ON / OFF*
Address bit 0 = 1 / Address bit 0 = 0
S8-7
ON / OFF*
Address bit 1 = 1 / Address bit 1 = 0
S8-8
ON / OFF*
Address bit 2 = 1 / Address bit 2 = 0
Table 7.44: S8 Dip switch settings (* = default)
RS232 port
You can enable or disable the RS232 port of the data distribution board with the S8-1 switch.
Set the baud-rate with the S8-3 switch.
When you connect the data distribution board to a hall display, you must enable the RS232
port of the data distribution board. The baud-rate for all hall displays is 19,200 baud. Only the
numeric display can also operate with a 9,600 baud connection.
Mode
Set the mode of the data distribution board with the S8‑2 switch. The data distribution board
can be:
–
A passive unit that receives data from the central control unit (passive mode).
–
An active unit that also transmits data to the central control unit (active mode).
Passive mode
You must put the data distribution board in the passive mode when:
–
You use data distribution board to send data to a hall display.
–
You use data distribution board for speak slowly or help signaling.
–
You only use the parallel outputs of the data distribution board.
If the data distribution board is in the passive mode, you must give it an address. This address
defines the application of the data distribution board. When you start the system for the first
time, you must push the de-init switch of the data distribution board to send its address to
the central control unit (refer to Initialization, page 178).
When you use the central control unit to erase the addresses of all units (refer to Initialization,
page 178), you must not push the de-init switch again. The central control unit remembers the
addresses of the passive data distribution boards when it is started again.
Addresses
If necessary, set the address of the data distribution board with the S8-6, S8-7 and S8-8
switches. This address is only used when the data distribution board is in the passive mode.
The address defines the application of the data distribution board.
7.18
228 en | Configuration
Conference System
2013.11 | V2.0 | DCN-NG_OM_V4.x
Operation Manual
Bosch Security Systems B.V.
Содержание DCN Next Generation
Страница 1: ...Conference System DCN Next Generation en Operation Manual ...
Страница 2: ......
Страница 288: ......
Страница 289: ......