LBB4404/00 Cobranet Interface
Use the LBB4404/00 Cobranet Interface to connect the system to a CobraNet network.
Network
Control In
1
2
3
4
5
6
7
8
C NC NO C NC NO C NC NO C NC NO C NC NO
1
2
48V
Control Out
1
2
3
4
5
48V
4
6
7
5
2
1
3
Figure 3.11: Front and rear views
1.
Display - Shows the configuration menu.
2.
Knob - Operates the configuration menu.
3.
Headphones socket - Headphones connection.
4.
Optical network sockets - Connects the cobranet interface to the optical network.
5.
CobraNet sockets - Connects the cobranet interface to the CobraNet network. The
CobraNet network contains the audio inputs and the audio outputs of the cobranet
interface.
6.
Control inputs - Connects the cobranet interface to external devices. Through the control
inputs, external devices can control the audio inputs and the audio outputs of the
cobranet interface.
7.
Control outputs - Sends the condition of the cobranet interface to external devices.
The following sections give more information about the mentioned subject:
–
Connection: LBB4404/00 Cobranet Interface, page 122.
–
Configuration: LBB4404/00 Cobranet Interface, page 196.
–
Operation: LBB4404/00 Cobranet Interface, page 241.
–
Technical Data: LBB4404/00 Cobranet Interface, page 278.
3.4
24
en | System Overview
Conference System
2013.11 | V2.0 | DCN-NG_OM_V4.x
Operation Manual
Bosch Security Systems B.V.
Содержание DCN Next Generation