Control capacity
Each device in the optical network has a number of nodes. The maximum number of nodes in
the optical network is 63.
Each device in the optical network has a certain delay that is represented with an equivalent
cable length. These values are important to be able to determine if optical network limit 3 is
not exceeded; refer to the sections Limits, page 77and Optical fiber length, page 80.
Device
Description
Nodes
Equivalent cable
length (m)
DCN-CCU2 /
DCN-CCUB2
Central Control Unit
2
24
DCN-WAP
Wireless Access Point
1
18
LBB4402/00
Audio Expander Analog
1
18
PRS-4DEX4
Audio Expander Digital
1
18
LBB4404/00
Cobra Net Interface
1
18
PRS-FINNA
Fiber Interface Non-Addressable
0
16
PRS-NSP
Network Splitter
1
34
LBB4419/00
Cable Couplers
0
20
INT-TX04
Digital 4 Channel Integrus Transmitter
1
18
INT-TX08
Digital 8 Channel Integrus Transmitter
2
24
INT-TX16
Digital 16 Channel Integrus Transmitter
4
36
INT-TX32
Digital 32 Channel Integrus Transmitter
8
59
Table 4.6: Nodes
Power capacity
It is important that the devices in the optical network do not use more total power than you
supply to the devices. Each device uses power and most devices do not have an independent
power supply.
Power consumption
The table shows the power each device in the optical network uses.
Device
Watt
LBB4402/00
7.6
LBB4404/00
10.5
PRS-NSP
3.9
PRS-FINNA
4.6
PRS-4DEX4
6.0
DCN-WAP
4.0
Table 4.7: Power consumptions