When a fault condition is resolved, the fault message will disappear. The messages CobraNet:
0xHH, Internal: Mute, Internal: 0xHH, Internal: Fatal, and No network go out of view when you
push the knob.
Fault status
Use the 1 Fault Status menu item to see condition messages of the cobranet interface. If there
is more than one message, the display shows the most important message.
Messages
Description
No Fault
The cobranet interface operates correctly.
Max. CH mismatch
You have attached an audio input or audio output to a channel
that does not exist.
CobraNet: 0xHH
The CobraNet module has a buddy link error. 0xHH is the
hexadecimal error code. Refer to the CobraNet documentation on
the DVD that was supplied with your system for more
information.
Internal: Mute
All audio inputs and audio outputs are muted.
Internal: 0xHH
The CobraNet module has a fault or an error. 0xHH is the
hexadecimal error code. Refer to the CobraNet documentation on
the DVD that was supplied with your system for more
information.
Internal: Fatal
The cobranet interface cannot start the firmware.
No network
The cobranet interface cannot find the optical network.
Table 8.18: Messages (low to high importance)